The MCY-1151 series industry pressure &
difference press transmitting instrument is a kind of reliable
product. It uses inthe industrial production and the technical
process to test the liquid, the gas and the steam presses,
parameters certainly and so on super atmospheric pressure,
negative pressure, difference pressure, current capacity, fluid
position, and density .It and other measuring appliances and
control device together form the industrial automation systems
and so on composition automatic detection, record, adjustment,
and control. It is widely used in department's process
examination control systems of metallurgy, coal, refinery, power
plant, chemical industry, light industry, food, and
environmental protection.
The MCY-1151 series transmitting instrument
input/output signal isolation, anti-electromagnetic interference
ability is very strong and suits on site installation. It has
the peaceful explosion-proof to select. Matches by the HART
intelligence equipment round card which designs specially, can
superimpose in the two-wire system 4~20 mA foundations outputs
the HART agreement’s digital signal. This product may carry by
the hand-hold or long-distance configuration to calibrate the
transmitting instrument and so on, may also turn on the HART
intelligence device management system.
MCY-1151-GP
Industry pressure transmitter
 Download
MCY-1151-DP
Industry difference press transmitter
 Download
|
Specification |
|
Range |
0.2,0.5,1,2,5,10,20,50,100 kPa 0.2,0.5,1,2,5,10,20,42
MPa |
|
Bridge voltage
|
14~36VDC(wire),the
standard 24VDC±5%,and ripple less than
1% |
|
Output signal |
4~20mADC(wire)T
or 0~5V,1~5V,0~10mA,4~20mA or 4~20mA input the pressure square
root,485 HART |
|
Accuracy |
0.1,0.25,0.5 % F·S |
|
Ambient temperature |
-25℃~90℃ |
|
Storage temperature |
-40℃~105℃ |
|
Relative Humidity |
0%~85% |
|
Zero drift |
the maximum positive value of the minimum range's 500%; the
maximum negative value of the minimum range 's 600% |
|
Damping Adjustment |
continuously adjustable within 0.2 to 1.67 seconds |
|
Overload effect |
less than the maximum range's
0.25% |
|
Static pressure effect |
Zero error is the maximum range's ± 0.5%, range error can be
corrected |
|
Temperature effect |
the maximum
:±0.5%/55℃ ;the minimum :±3.0%/55℃ |
|
Power effect |
less than the output range's
0.005%/V |
|
Load effect |
negligible |
|
position effect |
the zero maximum error can be generated 0.24kPa and
corrected, no effect on the range |
|
Stability |
Maximum range ± 0.25% / year (range> 1.6kPa); maximum
range ± 0.5% / year (range ≤ 1.6kPa) |
|
Operating method |
pressure
(GP) ,absolute
pressure (AP), high hydrostatic pressure (HP) differential
pressure (DP), differential pressure(DP),differential
pressure (DR) |
|
Medium |
stainless steel non-corrosive gases, liquids, steam |
|
Tipped pressure |
M20×1.5,NPT1/2 |
|
Overload |
150 % F·S |
(Outline-size) |
|